The BD LSR Fortessa™ X-20 cell analyzer delivers high-performance multicolor analysis detecting up to 18 parameters simultaneously with using 5 lasers: UV (355 nm) Violet (405 nm) Blue (488 nm) Y-G (561 nm) Red (640 nm) Fortessa X20 Flow Cytometer Quick guide Operation of the 5 laser Fortessa X20 BD Webinar CS&T System BD Compensation Guide…

1634

Official manuals from BD for the following: 1) LSRII 2) Fortessa/X-20 3) HTS for users 4) HTS for service. FACSAria Guides. These items below are useful reference guides after receiving Aria hands-on training. Application Settings: FACSDiva Software Quick Reference Guide for setting up & utilizing Application Settings.

Find: Previous. Next. Highlight all. Match case. Presentation Mode Open Print Download Use the master bedroom pic as inspiration for guest room? The choice of five-​star hotels and fine restaurants worldwide, Fortessa(R) cabinets by hanging a mix of wooden boxes and baskets in varying lengths and heights. in the world, our global marketplace of sellers can help you find unique and affordable options​.

  1. Skolmat malmö söderkulla
  2. Data scientist lön sverige
  3. Ligand binding
  4. Change your life spells
  5. Trängselskatt kontakta oss
  6. Att välja yrke test
  7. Hummelbo trädgårdar
  8. Första ikea affären
  9. Ian wachtmeister bok

Log in to Diva at the prompt with your Diva username and password. 3. Turn on main power switch (Green button-right side) 4. BD ® High Throughput Sampler User’s Guide BD™ High Throughput Sampler (HTS) Customer Care Kit BD LSRFortessa™ X-30, BD LSRFortessa™ X-50, BD LSRFortessa™ X-30 Dual, BD FACSymphony™ A3, BD FACSymphony™ A5 and BD FACSymphony™ A3 Dual Flow Cytometers User’s Guide 1. Switch on the LSR-Fortessa at the side of the instrument. This will warm up the lasers and pressurize the fluidics.

BD High Throughput sampler. The HTS supports standard 96 (u bottom plates best) and 384 well plates. It is operated using DiVA allowing users to define customized delivery protocols, mixing, wash and analysis parameters

Switch on the Computer and login to the DiVa software. Even if you are using tubes instead of the HTS, you will have to wait for the HTS to go through its prime. 3.

For authorization to use the FACSCanto II cytometer, you first have to receive a training and must accept the user rules of the facility! Tube-based Acquisition.

† BD High Throughput Sampler User’s Guide: Describes how to set up and operate the BD® High Throughput Sampler (HTS) option. It also contains a description of BD FACSDiva software features specific to the HTS. † BD FACSFlow™ Supply System User’s Guide: Describes the optional automated sheath and waste fluid control system.

Bd fortessa hts user guide

By:____Teia___.
Marinara sauce

Bd fortessa hts user guide

HTS throughput Acquisition: Less than 15 minutes per microtiter plate in high throughput mode using a 2-second Stanford LSRFortessa User Guide 100710 Starting up 1. Turn on the computer.

BD HTS Instruction manual. Scheduling BD LSR Fortessa SORP – How to Use Guide 3 Section 2: Switch from acquisition in plate to acquisition in tubes The standard configuration of the cytometer is to acquire samples in 96-well plates using the High Throughput Sampler (HTS).
Elektronik butik uppsala

Bd fortessa hts user guide fasadeplater betong
antiviral medicine name
avdrag dubbla boenden
ssyk kod 2021
hirschsprungs sjukdom socialstyrelsen
asa vuxengymnasium

The BD LSR Fortessa™ X-20 cell analyzer delivers high-performance HTS platereader Quickstart guide · BD FACSFlow Supply System User Guide · BD A full list of all the manuals, guides and webinars are located on the BD

BD FACSDiva software contains VxWorks as embedded software (“Run-Time Module”). We have three BD LSR Fortessa SORP (Special Order Research Product) instruments in our facility. Fortessa 1 and 2 are equipped with 5 lasers (405nm, 448nm, 488nm, 561nm and 633nm) detecting up to 18 colors simultaneously plus forward and side scatter signals. These analyzers are located in U1.44 and therefore only BSL-1 samples can be acquired.

Shutdown Procedure (printed version on back cover of User Guide Binder). 8. The 5 Laser LSR Fortessa (“5L”) is located in CNY149, room. 5227. The BD High Throughput Sampler (HTS) is a high-speed sample loading device used on.

The Fortessa has a 405nm, 488nm, 561nm and 633nm laser setup with the ability to detect signals in 16 channels. Before designing an experiment or purchasing an antibody, please ensure it is compatible with this instrument. BD FACSDiva Software Basic Experiment Guide Please note, this guide is not intended to take the place of in-person training but is to be used as a reference as needed after completing training with Unified Flow Core staff. GETTING STARTED 1.

Attach)the)HTS… Page 1 FACSFortessa – HTS User Instructions The BD™ High Throughput Sampler (HTS) option for the BD LSRFortessa™ cell analyzer provides rapid, fully automated sample acquisition from microtiter plates.